Compatible 6-Pin IBP Invasive Blood Pressure Adapter Cable with BD Interface for Draeger & Mindray Patient Monitors
mindray invasive blood pressure cable
,mindray invasive blood pressure adapter
,patient monitors invasive blood pressure cable
Product Overview
IBP (Invasive Blood Pressure) cables are dedicated patient monitor accessories that establish stable signal transmission between bedside monitors and disposable invasive blood pressure transducers. This category covers a full range of original and compatible IBP cables, including single-channel main cables, 1-to-2 dual-channel adapter cables and extension cables, designed for continuous invasive hemodynamic monitoring in ICUs, operating rooms, emergency departments and general wards.
General Specifications
|
Jacket Material |
Medical-grade TPU for most models, with abrasion and flex resistance |
|
Cable Color |
Grey as standard |
|
Cable Length |
Ranges from 0.3m to 3.5m to suit different clinical setups |
|
Monitor-end Connectors |
6-pin, 11-pin, 12-pin round, 14-pin and other proprietary interfaces |
|
Transducer-end Interfaces |
Abbott, Utah, B.Braun, BD, Edwards, Argon and other mainstream IBP connector standards |
|
Medical Device Classification |
Class I / Class II / Class III options available by model |
|
Disinfection Compatibility |
UV disinfection, infrared disinfection, ozone disinfection (varies by SKU) |
|
Place of Origin |
Guangdong, China |
|
Customization |
OEM/ODM services supported for selected models |
Compatibility
This cable portfolio is compatible with major patient monitor brands and series worldwide, including:
- Mindray: uMEC, iMEC, IPM, T, N, BeneView series
- PH-ILIPS: 78205, 78345 and classic patient monitor modules
- Nihon Kohden: standard IBP interface monitors
- Biolight: A, Q, S, P series
- Spacelabs: Ultraview, 700-0028-00 series
- GE: DASH3000, Marquette series
- Draeger, Comen, Jinjiang Electronics and other domestic and international monitor platforms
All cables are engineered to match the pin definition and mechanical structure of original monitor interfaces.
Certifications
All products in this category are CE certified and manufactured under an ISO13485 compliant quality management system. Selected models meet additional international medical safety standards, fulfilling regulatory requirements for medical device distribution in global markets.
Key Features
- Broad interface compatibility, covering mainstream IBP transducer standards and monitor brands worldwide
- Medical-grade TPU jacket withstands repeated bending, routine disinfection and long-term clinical use
- Built-in shielding structure reduces electromagnetic interference and ensures accurate, stable IBP waveform and data transmission
- Multiple product forms available: single-channel main cable, 1-to-2 dual-channel splitter, extension cable, original specification and cost-effective compatible versions
- Latex-free construction on most models, minimizing allergy risks for patients and clinical staff
- Each unit undergoes strict signal testing and quality inspection before shipment
- Flexible order options: sample order, single piece and bulk quantity supported
Package & Warranty
- Packaging: Individually packed in sealed bags or boxes, with outer cartons for bulk orders
- Warranty: 6 months to 24 months warranty, subject to specific product model
- Stock: Most standard models are kept in stock for fast delivery; made-to-order service available for customized specifications
- Sample: Sample purchase is supported for compatibility and quality verification
Usage Notes
- All IBP cables are medical accessories and shall only be operated and applied by qualified medical professionals.
- Please perform disinfection strictly in accordance with hospital infection control protocols and the disinfection type specified for each model before clinical use.
- Verify your patient monitor brand, model, interface pin count and transducer interface standard before ordering to ensure proper compatibility.
- Most products are supplied non-sterile. Do not immerse connectors and cable terminals in liquid to avoid internal circuit damage.
- Inspect cable appearance and connector integrity regularly; replace the cable in case of jacket damage, pin deformation or signal abnormality.