GE 2105489-001 Foam CO2 Canister Dust Filter Pads (40/Pack) for Aisys Avance Aespire Anesthesia Absorber
Product Overview
The GE Foam, CO2 Canister (REF 2105489-001) is a foam dust filter designed for use inside the reusable GE CO2 absorber canister (1407-7004-000) on GE anesthesia workstations. Supplied in a pack of 40 teardrop-shaped white foam pads, each pad is placed at the top and bottom of the absorbent bed to distribute gas flow and trap soda lime dust and particles, helping protect the anesthesia breathing circuit from contamination. During routine anesthesia delivery, these pads support even gas distribution through the absorbent bed and help maintain a clean breathing system. This GE 2105489-001 foam pad is a routine consumable for hospitals, surgical centers, and biomedical service organizations that maintain GE Aisys, Avance, and Aespire anesthesia machines. As a replacement for the legacy part number 1407-3201-000, it is used whenever the reusable canister is refilled with absorbent, supporting planned absorbent-change maintenance schedules.
Specifications
The parameters below reflect the product label and manufacturer data for REF 2105489-001.
|
Parameter |
Value |
|
Product name |
Foam, CO2 Canister |
|
Manufacturer part number (REF) |
2105489-001 |
|
Equivalent legacy part number |
1407-3201-000 |
|
Lot number |
51707 |
|
Product type |
Foam dust filter for the reusable CO2 absorber canister |
|
Pad shape |
Teardrop / oval white foam pad |
|
Quantity |
40 pads per pack |
|
Intended use |
Placed inside the reusable CO2 absorber canister (1407-7004-000; holds approximately 800 g of absorbent) to trap soda lime dust and particles |
|
Sterility |
Non-sterile; label bears a do-not-sterilize symbol |
|
Storage temperature |
-20 °C to +45 °C (-4 °F to 149 °F) |
|
Place of manufacture |
Made in USA |
|
Manufacturer |
Datex-Ohmeda, Inc. (GE Healthcare), Madison, WI |
Compatibility
This foam dust filter is designed for use with the GE reusable CO2 absorber canister (REF 1407-7004-000) on the following GE anesthesia workstations:
- GE Aisys / Aisys CS2
- GE Avance / Avance CS2
- GE Aespire, including Aespire View, 7900, 7100, and 100
- GE ADU
- GE 9100c
Please note: GE Carestation 600 and 750 series use a round CBS absorber canister, and this teardrop-shaped pad is not compatible with that canister design.
Certifications
Relevant medical certifications available upon request.
Key Features
- Pack of 40 teardrop-shaped foam dust filters for the GE reusable CO2 absorber canister
- Traps soda lime dust and particles before they enter the anesthesia breathing circuit
- Factory-matched shape for the GE reusable canister (1407-7004-000)
- Original GE / Datex-Ohmeda consumable, cross-referenced to legacy P/N 1407-3201-000
- Non-sterile replacement pad supplied for routine absorbent-change maintenance
Package & Warranty
- Packaging: 40 foam dust filter pads per pack; standard neutral export packaging
- Warranty: Standard 1-year manufacturer warranty
Usage Notes
This product is non-sterile and is not intended for direct patient contact. Place the pads inside the reusable CO2 absorber canister when refilling absorbent, following the workstation service manual. Store within the labeled temperature range. Please follow the standard clinical operation guidelines for medical consumables.